Public welfare concept

No trouble for the government, only for the happiness of the people.

Enterprise Information

Precautions and methods for maintenance of gas wall-mounted boilers

Release time:

2022/05/20 14:44

In the past, what problems often occurred during the use of gas wall-mounted boilers? How to judge whether the gas wall-mounted boilers should be repaired? Therefore, today we will talk about the precautions for the maintenance of gas wall-mounted boilers. After the gas wall-mounted boiler fails, the user can unplug the power plug of the wall-mounted boiler and close the gas main valve to ensure safety. Nowadays, multimedia is developing rapidly. Under the guidance of professionals, users can carry out simple maintenance of gas wall-mounted boilers through WeChat and other multimedia, such as leakage detection of gas circuits and heating systems. In addition, users should trust official website and are not allowed to call the maintenance number of unknown gas wall-mounted boilers without authorization. Pay attention to keep the bill to prevent disputes in the future; Find a good after-sales service to replace the machine. For construction personnel, in the specific gas wall-mounted boiler maintenance process, they should also fully understand the design and installation specifications of the overall heating system, and according to the performance characteristics of the product, popularize the daily maintenance instructions for users, and consider the user's usage habits to achieve Convenient use. Maintenance method: adjust the air supply pressure to reach the rated air supply pressure. 6. Control equipment failure. Gas boiler maintenance method: replace the control equipment. 7. The flame sensing needle does not touch the flame. Maintenance method: adjust the flame sensing needle to a position that can be exposed to fire or small fire. Try to be at the flame junction inside and outside the flame. 8. The flue is not installed correctly. Gas wall-mounted boiler maintenance method: It is forbidden to connect the intake and exhaust flue to the public flue and move it outdoors. 9. Install the intake and exhaust pipes in the public flue. Maintenance method of gas wall-mounted boiler: It is normal after removing the smoke pipe, and the smoke pipe is not connected correctly and needs to be reconnected.

see more...

Disclaimer: The content is forwarded from the Internet, and this website does not own the ownership and does not bear the relevant legal responsibility. If you find that this website is suspected of plagiarism, please go to contact us to report, and provide relevant evidence, once verified, this site will immediately delete the suspected infringing content.